HOME IKE CATER PROCEDURES KLYSTRONS THYRATRONS NIRP LLRF SLED

Thyratron Data Removal Form Installation Form Charts

Currently Installed Thyratron at 21-51    
Edit Station S/N Model Installed Date In HVRTM In Res V Install Notes Current Hv Hrs Thy Rem
21-51 4722 CX1937AX 18-MAR-2025 87329 6.3   9,718 N
1 - 1
Install History for Thyratron 4722    
Edit Station S/N Model Installed Date Removal Date In HVRTM Rem HVRTM Total HVRTM Install Notes Removal Reason Removal Notes In Res V Rem Res V CATER
21-51 4722 CX1937AX 18-MAR-2025   87329           6.3  
1 - 1
Previous Thyratrons installed at 21-51    
Edit Station S/N Model Installed Date Removal Date In HVRTM Rem HVRTM Total HVRTM Install Notes Removal Reason Removal Notes In Res V Rem Res V CATER
21-51 300298 L4888 23-AUG-2023 18-MAR-2025 77883.9 87329 9445.1   Other (see notes) Upgraded to E2V deuterium 3.55 3.55 173692
21-51 300255 L4888 10-JAN-2022 23-AUG-2023 70844.7 77858.6 7013.9   Unstable performance   3.5 6 164834
21-51 101209 L4888 29-OCT-2015 10-JAN-2022 39714 70844.7 31130.7   Other (see notes) Filament shorted. 3.4 5.3 154492
21-51 101106 L4888 28-OCT-2014 29-OCT-2015 32572 39714 7142   Unstable performance   3.84 6.5 128115
21-51 100992 L4888 12-OCT-2013 28-OCT-2014 25074 32572 7498   Unstable performance   3.75 10 120514
21-51 375 F310 24-JAN-2013 12-OCT-2013 20057 25074 5017   Unstable performance "Constant HVOC's & CB7 trips after ranging to 5.25VAC. Tried numerous lower res volts settings, still HVOCs" 6.5 5.25 111688
21-51 100848 L4888 01-OCT-2012 24-JAN-2013 17855 20057 2202   Reservoir open "Removed for will not range with Vres > 10V" 4 10 104269
21-51 100241 L4888 10-OCT-2011 01-OCT-2012 11413 17855 6442   Reservoir open :Vres @ 11.5 station in lo limit"   11.5 102940
21-51 100347     11-NOV-2011   11413       Hi Vres >6.5V no note where replacement from.    
21-51 100198 L4888 22-JAN-1998 09-JAN-2002     16882          
21-51 1227 CX1836A 03-MAY-1993 19-MAR-1998     7084          