HOME IKE CATER PROCEDURES KLYSTRONS THYRATRONS NIRP LLRF SLED

Thyratron Data Removal Form Installation Form Charts

Currently Installed Thyratron at 29-11    
Edit Station S/N Model Installed Date In HVRTM In Res V Install Notes Current Hv Hrs Thy Rem
29-11 300478 L4888 13-JUN-2025 55939.2 3.5   5,757 N
1 - 1
Install History for Thyratron 300478    
Edit Station S/N Model Installed Date Removal Date In HVRTM Rem HVRTM Total HVRTM Install Notes Removal Reason Removal Notes In Res V Rem Res V CATER
29-11 300478 L4888 13-JUN-2025   55939.2           3.5  
1 - 1
Previous Thyratrons installed at 29-11    
Edit Station S/N Model Installed Date Removal Date In HVRTM Rem HVRTM Total HVRTM Install Notes Removal Reason Removal Notes In Res V Rem Res V CATER
29-11 300155 L4888S 16-MAR-2024 13-JUN-2025 47833.1 55939.2 8106.1   Other (see notes) EOLC faults at 5kV 3.2 3.2 178064
29-11 300156 L4888S 19-MAR-2021 16-MAR-2024 32777.6 47833.1 15055.4   Unstable performance Very jittery 3.6 6.2 166924
29-11 000056 L4888 09-JUN-2017 19-MAR-2021 16918 32777.6 15835.2   Other (see notes) Swap in deuterium thyratron. Send this tube to FACET-II spares. 3.3 6.1 149463
29-11 101280 L4888 15-NOV-2016 09-JUN-2017 15564 16918 1354   Other (see notes) For use as a source tube. 3.6 3.6 135554
29-11 101188 L4888 10-SEP-2015 15-NOV-2016 7021 15564 8543   Reservoir open Quit firing. 3.4 6.35 133616
29-11 100929 L4888 26-OCT-2012 10-SEP-2015 109882 130000 20118 MO3 Other (see notes) Filament over-current. 4.12 6.5 126889
29-11 100863 L4888 27-FEB-2012 29-OCT-2012 105630.5 109882 4252   Other (see notes) End of life. 4.3 10 103314
29-11 100598 L4888 25-FEB-2011 27-FEB-2012 99676 105630.5 5954.5   Reservoir open Reservoir open, disposition to scrap   11 0
29-11 100333 L4888 10-JUL-2003 04-JAN-2008     5162          
29-11 787 F241 30-SEP-1996 10-JUL-2003     13274          
29-11 198 F310 26-APR-1993 22-APR-1997     20143          