HOME IKE CATER PROCEDURES KLYSTRONS THYRATRONS NIRP LLRF SLED

Thyratron Data Removal Form Installation Form Charts

Currently Installed Thyratron at 29-51    
Edit Station S/N Model Installed Date In HVRTM In Res V Install Notes Current Hv Hrs Thy Rem
29-51 300502 L4888 04-MAY-2026 180937.5 3.6   1,757 N
1 - 1
Install History for Thyratron 300502    
Edit Station S/N Model Installed Date Removal Date In HVRTM Rem HVRTM Total HVRTM Install Notes Removal Reason Removal Notes In Res V Rem Res V CATER
29-51 300502 L4888 04-MAY-2026   180937.5           3.6  
1 - 1
Previous Thyratrons installed at 29-51    
Edit Station S/N Model Installed Date Removal Date In HVRTM Rem HVRTM Total HVRTM Install Notes Removal Reason Removal Notes In Res V Rem Res V CATER
29-51 300224 L4888 17-NOV-2020 04-MAY-2026 151016.7 180937.5 29920.8   Unstable performance   4 4.6 184107
29-51 160027 L4888 22-JUL-2017 17-NOV-2020 139129 151016.7 11861.7   Unstable performance   3.4 6.6 147518
29-51 101174 L4888 26-MAY-2015 22-JUL-2017 126079 139129 13050   Unstable performance Ranging unable to stop drop-outs. 3.48 6.5 136140
29-51 101056 L4888 18-JUN-2014 26-MAY-2015 119655 126079 6424   Other (see notes) EOL 3.59 8 125328
29-51 101005 L4888 01-NOV-2013 18-JUN-2014 114778 119655 4877   Mechanical failure   3.75 9.44 117905
29-51 274 F241 19-MAR-2011 01-NOV-2013 97807 114778 16971   Reservoir open "Thyratron end of life (10.5V)" 0 10.5 112375
1 - 6