HOME IKE CATER PROCEDURES KLYSTRONS THYRATRONS NIRP LLRF SLED

Thyratron Data Removal Form Installation Form Charts

Currently Installed Thyratron at 25-81    
Edit Station S/N Model Installed Date In HVRTM In Res V Install Notes Current Hv Hrs Thy Rem
25-81 300498 L4888 02-JUN-2026 85063 3.5   1,474 N
1 - 1
Install History for Thyratron 300498    
Edit Station S/N Model Installed Date Removal Date In HVRTM Rem HVRTM Total HVRTM Install Notes Removal Reason Removal Notes In Res V Rem Res V CATER
25-81 300498 L4888 02-JUN-2026   85063           3.5  
1 - 1
Previous Thyratrons installed at 25-81    
Edit Station S/N Model Installed Date Removal Date In HVRTM Rem HVRTM Total HVRTM Install Notes Removal Reason Removal Notes In Res V Rem Res V CATER
25-81 300291 L4888 19-NOV-2022 02-JUN-2026 65567 85063 19496   Unstable performance   3.2 4 184308
25-81 300167 L4888 29-SEP-2018 19-NOV-2022 49803 65567 15764 4 hour tube. Unstable performance   3.25 6.26 160889
25-81 101257 L4888 31-MAR-2016 29-SEP-2018 35517 49803 14286   Unstable performance Going to FACET II spares. 3.3 6.3 140231
25-81 101017 L4888 10-DEC-2013 31-MAR-2016 20098 35517 15419   Reservoir open   3.55 8.7 131096
25-81 100790 L4888 26-JUL-2012 10-DEC-2013 10909 20098 9189   Reservoir open "Res = 10V. Jitter, noisy backswing" 4.22 10 113444
25-81 100770 L4888 15-AUG-2011 26-JUL-2012 3615 10909 7294   Reservoir open "Tube will not switch Vres 9.04V"   9.04 101952
25-81 100427 L4888 03-JUN-2005 13-AUG-2011     24265          
25-81 792 F241 07-OCT-1996 03-MAY-2005     12922          
25-81 238 F310 01-NOV-1993 07-JAN-1998     23722          
1 - 9

nobody