HOME IKE CATER PROCEDURES KLYSTRONS THYRATRONS NIRP LLRF SLED

Thyratron Data Removal Form Installation Form Charts

Currently Installed Thyratron at 29-71    
Edit Station S/N Model Installed Date In HVRTM In Res V Install Notes Current Hv Hrs Thy Rem
29-71 300475 L4888 03-JUN-2025 73805.3 3.4   7,052 N
1 - 1
Install History for Thyratron 300475    
Edit Station S/N Model Installed Date Removal Date In HVRTM Rem HVRTM Total HVRTM Install Notes Removal Reason Removal Notes In Res V Rem Res V CATER
29-71 300475 L4888 03-JUN-2025   73805.3           3.4  
1 - 1
Previous Thyratrons installed at 29-71    
Edit Station S/N Model Installed Date Removal Date In HVRTM Rem HVRTM Total HVRTM Install Notes Removal Reason Removal Notes In Res V Rem Res V CATER
29-71 300284 L4888 27-JUN-2022 03-JUN-2025 62980.8 73805.3 10824.5   Unstable performance   3.55 5.4 177793
29-71 300235 L4888 31-MAR-2021 27-JUN-2022 55869.3 62980.8 7111.5   Unstable performance   3.65 6 157916
29-71 101220 L4888 21-NOV-2015 31-MAR-2021 31938 55843 23905   Unstable performance   3.4 6.1 150049
29-71 101001 L4888 28-SEP-2013 21-NOV-2015 16556 31938 15382   Reservoir open   3.7 6.85 128830
29-71 100911 L4888 10-JUL-2012 28-SEP-2013 8819 16556 7737   Unstable performance "Res >10.3V, will not reach peak set voltage w/o HVOC's continuously. Unable to range out." 4.2 10.3 111163
29-71 100772 L4888 05-JUL-2011 10-JUL-2012 1255 8819 7564   Unstable performance "EOL last set @ 8+ vres"   8.5 101667
29-71 242 F310 19-NOV-1993 16-SEP-2005     36592          
1 - 7

nobody