Feedback
HOME
IKE
CATER
PROCEDURES
KLYSTRONS
THYRATRONS
NIRP
LLRF
SLED
Thyratron Data
Removal Form
Installation Form
Charts
Station
30-11
S/N
300338
Currently Installed Thyratron at 30-11
Edit
Station
S/N
Model
Installed Date
In HVRTM
In Res V
Install Notes
Current Hv Hrs
Thy Rem
30-11
300338
L4888
06-JUN-2024
165990
3.75
13,784
N
1 - 1
Install History for Thyratron 300338
Edit
Station
S/N
Model
Installed Date
Removal Date
In HVRTM
Rem HVRTM
Total HVRTM
Install Notes
Removal Reason
Removal Notes
In Res V
Rem Res V
CATER
30-11
300338
L4888
06-JUN-2024
165990
3.75
1 - 1
Previous Thyratrons installed at 30-11
Edit
Station
S/N
Model
Installed Date
Removal Date
In HVRTM
Rem HVRTM
Total HVRTM
Install Notes
Removal Reason
Removal Notes
In Res V
Rem Res V
CATER
30-11
300250
L4888
29-SEP-2021
06-JUN-2024
153062.9
165990
12927.1
Unstable performance
3.3
6
167930
30-11
300203
L4888
28-JAN-2021
29-SEP-2021
149110
153058.4
3948.4
Other (see notes)
Blower failed causing thyratron to overheat and cause shroud to encase tube.
3.2
3.6
152935
30-11
101173
L4888
07-MAY-2015
28-JAN-2021
121905
149110
27205
Other (see notes)
Not firing
3.4
6.2
148742
30-11
100846
L4888
22-NOV-2011
05-MAY-2015
97488
121905
24417
Reservoir open
8
124819
30-11
100428
L4888
03-JUN-2005
20-MAY-2011
24124
30-11
285
F310
25-MAY-1999
03-JUN-2005
8540
30-11
2209
CX1836A
05-MAR-1993
05-MAY-1999
12166
1 - 7