BABAR Publications

Detailed Index as of April 19, 2024 02:47

NOTE-0302 Monitoring Requirements of the BaBar Silicon Vertex Tracker
Doc Type BaBar Notes
Record Created December 21, 2001
Author List? No
Abstract
content_type = "text/plain"
user_agent   = "Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)"
moz          = "Mozilla/5.0 "
moz_version  = "5"
This document specifies the requirements for many of the monitoring tasks associated with the silicon vertex tracker (SVT). It covers monitoring of background radiation levels for diagnostic and detector protection purposes, monitoring of the positions of the SVT support cones relatibe to the B1 magnets for safety alignment purposes, monitoring of the temperatures of the high density interconnects (HDI's), the SVT mechanical support, and any temperature-sensitive monitoring components, and monitoring of the humidity level in the interaction region. It does not cover the monitoring of power supply currents for the SVT detectors and readout electronics. It also does not cover monitoring of parameters in the interaction region directly related positions of PEP-II magnets, temperatures of machine components, beam position, vacuum,etc.
Other Authors Burchat, Patricia
Kirkby, David
Revisions and Files 1 revised April 22, 2002
File Date
Thumbnails
File Name File Type File Format File Size (Kb) Comments
14-FEB-2002 BaBar302.pdf Paper (journal paper or conference submission by BABAR Collaboration) pdf 493.20
14-FEB-2002 BaBar302.ps.gz Paper (journal paper or conference submission by BABAR Collaboration) ps.gz 267.31
12-FEB-2002 babar-note-abs-302.txt Abstract txt 0.83 none